DWEERTM Dual Work Exchange Energy Recovery
Standards
• Flowserve
Operating Parameters
• Brine flows to 350 m3/h (1.4 MGD); greater flows can be achieved by placing multiple DWEER units in parallel
• Pressures to 75 bar (1090 ft)
• Highest efficiency energy recovery device available
• Noise levels below 83 dBa
• Self-adjustable to changing operating conditions
• Super duplex stainless steel or fiber-reinforced plastic pressure vessel
• No leakage lubrication required
• LinX™ valve regulates flow into vessels
• Proven long-term reliability
• Capable of passing solids (no additional strainers required)
• System responsibility with integrated controls
• Slow operating speed
• Smooth increase and decrease of system pressure during startup and shutdown