PHL-Mag Centerline Mounted, Magnetic Drive

PHL-Mag Centerline Mounted, Magnetic Drive

Standards
• API 685, latest edition


Operating Parameters
• Flows to 900 m3/h (4000 gpm)
• Heads to 400 m (1300 ft)
• Pressures to 40 bar (600 psi)
• Temperatures to 200°C (400°F)
• Motor sizes to 130 kW (175 hp)

• Magnetic drive design
• 100% leak-free sealless design
• Custom-tuned hydraulics
• State-of-the-art diffuser technology
– Project-specific designs
• Alloy C-276 containment shell hydrotested to 60 bar (900 psi)
• Product lubricated silicon carbide bearings
• Replaceable diffusers

• Top suction nozzle
• PHL centerline mounted

flowserve pump